Changes between Version 1 and Version 2 of HardwareUsersGuides/RadioBoard_v1.4/Usage/TxDCOffset


Ignore:
Timestamp:
Apr 9, 2007, 11:40:35 PM (17 years ago)
Author:
murphpo
Comment:

--

Legend:

Unmodified
Added
Removed
Modified
  • HardwareUsersGuides/RadioBoard_v1.4/Usage/TxDCOffset

    v1 v2  
    1313The calibration algorithm is not publically available. However, we do distribute an FPGA configuration file which executes the calibration process automatically.
    1414
    15  1) Download a copy configuraiton file - TxDCO_Calibrate.bit
    16  1) Use the DIP switch on the WARP FPGA Board to select which radios should be calibrated. Each switch position corresponds to a radio. The LSB (Radio #1) is the bottom switch; MSB (Radio #4) is the top.
    17  1) Connect a serial cable to the FPGA board and set your terminal emulator to 57600bps
    18  1) Power on the FPGA board and wait for a few minutes; this allows components to warm up
    19  1) Configure the FPGA using TxDCO_Calibrate.bit
    20  1) The terminal will display the status as it runs. Wait for the calibration of each radio to complete.
     15 1. Download a copy configuraiton file - TxDCO_Calibrate.bit
     16 1. Use the DIP switch on the WARP FPGA Board to select which radios should be calibrated. Each switch position corresponds to a radio. The LSB (Radio #1) is the bottom switch; MSB (Radio #4) is the top.
     17 1. Connect a serial cable to the FPGA board and set your terminal emulator to 57600bps
     18 1. Power on the FPGA board and wait for a few minutes; this allows components to warm up
     19 1. Configure the FPGA using TxDCO_Calibrate.bit
     20 1. The terminal will display the status as it runs. Wait for the calibration of each radio to complete.
    2121
    2222You can repeat this process whenever needed. In our experience, calibration values are fairly static over time but do vary with temperature.