Changes between Version 9 and Version 10 of OFDMReferenceDesign/SDK


Ignore:
Timestamp:
May 3, 2012, 4:41:45 PM (12 years ago)
Author:
murphpo
Comment:

--

Legend:

Unmodified
Added
Removed
Modified
  • OFDMReferenceDesign/SDK

    v9 v10  
    107107
    108108 * Do not power cycle the FPGA Board or disconnect the JTAG/USB cable while SDK is running. Always quit SDK first.
    109    * If an active SDK session loses the JTAG connection, the JTAG cable will get locked and will fail to function for the current or future SDK sessions. To fix this run iMPACT (Programs->Xilinx Design Suite 13.4->ISE Design Tools->32/64-bit Tools->iMPACT), double-click Boundary Scan, choose Output->Cable Reset. Then re-launch SDK to reestablish the JTAG connection.
     109   * If an active SDK session loses the JTAG connection, the JTAG cable will get locked and will fail to function for the current or future SDK sessions. The SDK may freeze in this state. Use Task Manager to kill eclipse.exe and xmd.exe. Then run iMPACT (Programs->Xilinx Design Suite 13.4->ISE Design Tools->32/64-bit Tools->iMPACT), double-click Boundary Scan, choose Output->Cable Reset. Then re-launch SDK to reestablish the JTAG connection.
    110110
    111111 * The XMD console view in SDK is useful for debugging issues when communicating via JTAG. Open Xilnx Tools->XMD Console. In the new XMD Console tab, type {{{verbose}}} in the command box (bottom of the tab).