Changes between Version 6 and Version 7 of WARPLab6/Specifications


Ignore:
Timestamp:
Dec 16, 2009, 8:48:50 AM (14 years ago)
Author:
mduarte
Comment:

--

Legend:

Unmodified
Added
Removed
Modified
  • WARPLab6/Specifications

    v6 v7  
    4242 * MAX2829 specifies the RSSI bandwidth is 3MHz but we have observed that RSSI bandwidth spans nearly the full bandwidth of the RF path (RF path bandwidth is determined by Tx/RF LPFs corner frequency settings). Users are recommended to test RSSI bandwidth directly in their setup to see its characteristics directly; try transmitting a chirp (sweeping sinusoid) and plotting the RSSI vs. time. See WARPLab example 'warplab_siso_example_TxRx_BandwidthChange.m'.
    4343 * The RSSI signal is sampled by its own ADC (independent of I/Q ADCs). In WARPLab, the RSSI ADC is clocked at 10 MHz (1/4 of the rate of the I/Q ADCs).
    44  * The 2x2 MIMO bitstream allows storage of RSSI samples on RSSI buffers that can be read directly from MATLAB Workspace. 4x4 MIMO bitstream does not support storage of RSSI values.
     44