    1111 * '''My project takes a longtime to generate the bitstream.  Then it doesn't work.  What's wrong?'''[[BR]]
    1212 * '''Everything looks right, but when I try downloading to the board with iMPACT, nothing happens.'''
     13 * '''I get an error: "built in linker script:[line#] cannot move location counter backwards (from [address1] to [address2])"'''
    1314 * '''When all else fails...'''
    1415
     
    6768  * Try restarting !TeraTerm and iMPACT. If this doesn't work, try the other methods listed in the '''Download Peripheral Test to the Board''' section located '''[wiki:peripheral_test/execution here]'''.
    6869
     70* '''I get an error: "built in linker script:[line#] cannot move location counter backwards (from [address1] to [address2])'''
     71  * You need to regenerate the linker script because of changes to your code.  Repeat step 6 of '''Setting up the Peripheral Test in XPS''': '''[wiki:peripheral_test/sw_setup here.]''' Click '''OK''' at the request to overwrite the previous script.