Changes between Version 7 and Version 8 of WARPLab6/Benchmarks
- Timestamp:
- Dec 10, 2009, 11:30:04 AM (15 years ago)
Legend:
- Unmodified
- Added
- Removed
- Modified
-
WARPLab6/Benchmarks
v7 v8 7 7 The two important metrics are the time to update a parameter in the radio setup and the time for a complete over-the-air transmission. 8 8 9 First is the time for just a command: 9 The time for a parameter setup is 15 ms. 10 10 11 [[Image(WARPLab/Images:benchmark_cmd.pdf, 200px)]] 11 12 12 13 13 14 Time to complete a full data transmission. The time for filling up the Tx buffer and reading the Rx buffer depends on number of samples transmitted (max of 2^14^). For a SISO link where one full buffer is written to and read from, it takes 2300 ms to complete the transaction. Additional radios will take increased time. 15 14 16 [[Image(WARPLab/Images:benchmark_data.pdf, 800px)]] 15 17